SC-20-IMP

SC-20-IMP
Technical Datasheet SC-20-IMPTechnical Datasheet SC-20-IMP
CE Test Certificate CEM-CY-01/0025-5.2CE Test Certificate CEM-CY-01/0025-5.2
Description

ALPHANUMERIC 6000 Divisions

· INOX shell
· 6 digits display of 7 red segments
· Alphanumeric 4 lines display with 20 characters per line
· Configuration and adjustment by keyboard mobile type
· RS-232 series communication
· Text edition by PC keyboard 
· Mains
· Integrated printer (optional)

Versions
· SC 20/A: Analogic indicator
· SC 20/D: Digital load cells indicator
· SC 20/BAT12: For external battery 12 V indicator
· SC 20/BB: Bibáscula / Bibascule


Basic configuration

· Truck-weighing
· Pieces Counter
· Axles-weighing
· Multirange
· Communications 2 RS-232 ports
· Compatible protocols
· Hardware
- Clock-Calendar
- Connector for PC keyboard (PS/2)
· Languages Spanish, English, French, Italian & Portuguese
 


Sofware
- Piececounter
- Piece-Tare-Codes
- Truck weighing
- Axes weighing
 


Optional hardware
- External 12V battery.
- 2 Optocoupled inputs and 6 relay outputs
- Converts 1st or 2nd RS232 optocoupled channel to RS485.
- Converts 1st or 2nd RS232 channel to RF
- Bibascule
- DSD feature (until 4000 weighings)


Optional
· Special programs
· Bibascule
· Traffic lights
 


Available printers
· LX-300 from EPSON
· SRP 275 from SAMSUNG
· SP298 from STAR
· TM295 from EPSON
 


Technical data
Accuracy class III
Maximum number of verification scale intervals 10000
Load cell excitation power supply 8 V DC
Max. signal voltage for dead load 16 mV
Minimum signal voltage for dead load 0 mV
Minimum input voltage per verification scale interval 1.33 µV
Measuring range minimum voltage 8 mV
Measuring range maximum voltage 24 mV
Minimum load cell impedance 80 ?
Maximum load cell impedance 2000 ?
Minimum temperature range -10º C
Maximum temperature range 40º C
Power supply requirements (options SC20/A or SC20/D) 220 V AC
Power supply requirements (option SC20/BAT12) 12 V DC
Sense system Available
Load cell cable length
4 wire systems 5 m/mm2
6 wire systems No limit

 