ANTIV-AL/AC-2

Capacities: 15 ... 150 t.
Technical Datasheet AC-2Technical Datasheet AC-2
Description

Capacity: 15 - 20 - 25 - 30 - 35 - 50 - 75 - 100* - 200* t

Compression Load Cell
Up to 4000 divisions OIML-R60
Fully welded. Protected against humidity
IP-69K (EN DIN 40050-9)
Fully Stainless Steel
Wuth Gas Dischargers to protect against
atmospheric discharges
No corner adjustment needed

REINFORCED TANK WEIGH MODULE
Installation block system
Easy load cell exchange
External adjustments:
- Plate or tank inclination
- Plate or tank uprising

Technical Data

Accuracy class C3-C4
Rated Output 2 ± 0.1% mV/V
Vmin Emax/10000
Excitation voltage 5÷15V
Input resistance 800 ± 3?
Output resistance 700 ± 3?
Temperature Compensation -10ºC/+40ºC
Temperature limits -30ºC/ +70ºC
Insulation resistance > 5000 M?